HOVER AUTO IntiIoT (IT6RTSIN)
HOVER AUTO (AU6RTSIN)
HOVER AUTO IntiIoT (IT9RTSIN)
HOVER AUTO (AU8CXSIN)
HOVER MAX (MX5TXSIN)
HOVER AUTO IntiIoT (IT6RTSIN)
HOVER® AUTO IntiIoT with 6" RAC Mattress
HOVER® AUTO IntiIoT with 6" RAC Mattress
Specifications | System Controller (AUTO IntiIoT) |
---|---|
Dimension (cm) | L 30 x W15 x H25 |
Weight | ~ 3.1 Kg |
Pump Flow Rate | ~ 17 LPM |
Automatic Modes | Dynamic, Comfort, Firm, Incline |
Sensors and Alarms | Low Pressure, System Failure, Power Failure |
Pressure Adjustment levels | 5 Steps |
Battery Backup | 30 min |
Alternating Cycle Time (min) | 5, 10 (default), 15, 20 |
Case Material | Durable and non-reactive PC |
Input Voltage | AC 220-240V / 50Hz |
IoT Connectivity | Bluetooth |
Certifications | CE, IEC 60601-1, IEC 60601-1-2, IEC 62304, IP 41, ISO 13485 |
Specifications | Mattress (TS-505) |
---|---|
Dimension (cm) | L 200 x W90 x H15 |
Weight | ~ 4.2 Kg |
Offloading Cycles | 1-in-2 |
Number of Cells | 20 Retainer Air Cell |
Load Range | 30 - 240 Kg |
Pillow Function | 3 Cells |
Top Coverlet Material | 4-way stretchable vapor permeable water resistant Nylon PU |
Base Material | 210D Nylon TPU |
Air Cell Material | 70D Nylon TPU |
Transport Mode | Yes |
Emergency CPR | Single Pull |
Certification | CE, FR, IEX0 |
HOVER AUTO (AU6RTSIN)
HOVER® AUTO with 6" RAC Mattress
Specifications | System Controller (AUTO) |
---|---|
Dimension (cm) | L 30 x W15 x H25 |
Weight | ~ 3.0 Kg |
Pump Flow Rate | ~ 17 LPM |
Automatic Modes | Dynamic, Comfort, Firm, Incline |
Sensors and Alarms | Low Pressure, System Failure, Power Failure |
Pressure Adjustment levels | 5 Steps |
Battery Backup | 30 min |
Alternating Cycle Time (min) | 5, 10 (default), 15, 20 |
Case Material | Durable and non-reactive PC |
Input Voltage | AC 220-240V / 50Hz |
Fuse | 1A Slow Blow Out |
Certifications | CE, IEC 60601-1, IEC 60601-1-2, IP 41, ISO 13485 |
Specifications | Mattress (TS-505) |
---|---|
Dimension (cm) | L 200 x W90 x H15 |
Weight | ~ 4.2 Kg |
Offloading Cycles | 1-in-2 |
Number of Cells | 20 Retainer Air Cell |
Load Range | 20 - 240 Kg |
Pillow Function | 3 Cells |
Top Coverlet Material | 4-way stretchable vapor permeable water resistant Nylon PU |
Bottom Cover Material | 210D Nylon TPU |
Air Cell Material | 70D Nylon TPU |
Transport Mode | Yes |
Emergency CPR | Single Pull |
Certification | CE, FR, IEX0 |
HOVER AUTO IntiIoT (IT9RTSIN)
HOVER® AUTO IntiIoT with 9" RAC + CoC Mattress
HOVER® AUTO IntiIoT with 9" RAC + CoC Mattress
Specifications | System Controller (AUTO IntiIoT) |
---|---|
Dimension (cm) | L 30 x W15 x H25 |
Weight | ~ 3.1 Kg |
Pump Flow Rate | ~ 17 LPM |
Automatic Modes | Dynamic, Comfort, Firm, Incline |
Sensors and Alarms | Low Pressure, System Failure, Power Failure |
Pressure Adjustment levels | 5 Steps |
Battery Backup | 30 min |
Alternating Cycle Time (min) | 5, 10 (default), 15, 20 |
Case Material | Durable and non-reactive PC |
Input Voltage | AC 220-240V / 50Hz |
IoT Connectivity | Bluetooth |
Certifications | CE, IEC 60601-1, IEC 60601-1-2, IEC 62304, IP 41, ISO 13485 |
Specifications | Mattress (TS-508) |
---|---|
Dimension (cm) | L 200 x W90 x H23 |
Weight | ~ 8.5 Kg |
Offloading Cycles | 1-in-2 and static bottom |
Number of Cells | 20 / 22 Retainer Air Cell + Cell on Cell |
Load Range | 30 - 250 Kg |
Pillow Function | 3 Cells |
Top Coverlet Material | 4-way stretchable vapor permeable water resistant Nylon PU |
Base Material | 210D / 600D Nylon TPU |
Air Cell Material | 70D Nylon TPU |
Transport Mode | Yes |
Emergency CPR | Single hand Dual Pull |
Certification | CE, FR, IEX0 |
HOVER AUTO (AU8CXSIN)
HOVER® AUTO with 8" CoC Mattress
HOVER® AUTO with 8" CoC Mattress
Specifications | System Controller (AUTO) |
---|---|
Dimension (cm) | L 30 x W15 x H25 |
Weight | ~ 3.0 Kg |
Pump Flow Rate | ~ 17 LPM |
Automatic Modes | Dynamic, Comfort, Firm, Incline |
Sensors and Alarms | Low Pressure, System Failure, Power Failure |
Pressure Adjustment levels | 5 Steps |
Battery Backup | 30 min |
Alternating Cycle Time (min) | 5, 10 (default), 15, 20 |
Case Material | Durable and non-reactive PC |
Input Voltage | AC 220-240V / 50Hz |
Fuse | 1A Slow Blow Out |
Certifications | CE, IEC 60601-1, IEC 60601-1-2, IP 41, ISO 13485 |
Specifications | Mattress (XS-T04) |
---|---|
Dimension (cm) | L 200 x W90 x H20 |
Weight | ~ 6.5 Kg |
Offloading Cycles | 1-in-2 |
Number of Cells | 18 Cell-on-Cells |
Load Range | 20 - 250 Kg |
Pillow Function | 3 Cells |
Top Coverlet Material | 4-way stretchable vapor permeable water resistant Polyester PU |
Bottom Cover Material | 600D Polyester PVC |
Air Cell Material | 70D Nylon TPU |
Transport Mode | Yes |
Emergency CPR | Dual Pull |
Certification | CE |
HOVER MAX (MX5TXSIN)
HOVER® MAX with 5" Mattress
HOVER® MAX with 5" Mattress
Specifications | System Controller (MAX) |
---|---|
Dimension (cm) | L 30 x W15 x H25 |
Weight | ~ 2.7 Kg |
Pump Flow Rate | ~ 17 LPM |
Automatic Modes | Dynamic, Static |
Sensors and Alarms | Low Pressure |
Pressure Adjustment levels | 5 Steps |
Panel Lock | Yes |
Alternating Cycle Time (min) | 10 min |
Case Material | Durable and non-reactive PC |
Input Voltage | AC 220-240V / 50Hz |
Fuse Rating | 1 A SLow Blowout |
Certifications | CE, IP 41, ISO 13485 |
Specifications | Mattress (XS-T05) |
---|---|
Dimension (cm) | L 200 x W90 x H13 |
Weight | ~ 4.9 Kg |
Offloading Cycles | 1-in-2 and static bottom |
Number of Cells | 16 Air Cell |
Load Range | 30 - 210 Kg |
Pillow Function | 3 Cells |
Top Coverlet Material | 4-way stretchable vapor permeable water resistant Nylon PU |
Base Material | 600D Polyester PVC |
Air Cell Material | 70D Nylon TPU |
Transport Mode | Yes |
Emergency CPR | Single Pull |
Certification | CE |