• HOVER® is a fully digital controller with IOT*

    In an era of big data, personalized medicine and artificial intelligence, the importance of engineering, especially in medicine, is increasing.
    * IOT is an optional enhancement available in HOVER AUTO IntiIoT model
HOVER AUTO IntiIoT (IT6RTSIN)
HOVER AUTO (AU6RTSIN)
HOVER AUTO IntiIoT (IT9RTSIN)
HOVER AUTO (AU8CXSIN)
HOVER MAX (MX5TXSIN)
HOVER AUTO IntiIoT (IT6RTSIN)

HOVER® AUTO IntiIoT with 6" RAC Mattress

Specifications
System Controller (AUTO IntiIoT)
 Dimension (cm)L 30 x W15 x H25
Weight~  3.1 Kg
Pump Flow Rate ~ 17 LPM
Automatic Modes Dynamic, Comfort, Firm, Incline
Sensors and AlarmsLow  Pressure, System Failure, Power Failure
Pressure Adjustment levels 5 Steps
Battery Backup 30 min
Alternating Cycle Time (min)
 5, 10 (default), 15, 20
Case Material Durable and non-reactive PC
Input VoltageAC 220-240V / 50Hz
IoT ConnectivityBluetooth
Certifications CE,  IEC 60601-1, IEC 60601-1-2,
IEC 62304, IP 41, ISO 13485
 Specifications
Mattress (TS-505)
 Dimension (cm)L 200 x W90 x H15
 Weight~  4.2 Kg
Offloading Cycles 1-in-2
 Number of Cells 20 Retainer Air Cell
 Load Range 30 - 240 Kg
 Pillow Function 3 Cells
 Top Coverlet Material 4-way stretchable vapor permeable water resistant
Nylon PU
 Base Material210D Nylon TPU
 Air Cell Material70D Nylon TPU
 Transport ModeYes
 Emergency CPRSingle Pull
CertificationCE, FR, IEX0
HOVER AUTO (AU6RTSIN)

HOVER® AUTO with 6" RAC Mattress

Specifications
System Controller (AUTO)
 Dimension (cm)L 30 x W15 x H25
Weight~ 3.0 Kg
Pump Flow Rate ~ 17 LPM
Automatic Modes Dynamic, Comfort, Firm, Incline
Sensors and AlarmsLow Pressure, System Failure, Power Failure
Pressure Adjustment levels 5 Steps
Battery Backup 30 min
Alternating Cycle Time (min)
 5, 10 (default), 15, 20
Case Material Durable and non-reactive PC
Input VoltageAC 220-240V / 50Hz
Fuse 1A Slow Blow Out
Certifications CE, IEC 60601-1, IEC 60601-1-2,
IP 41, ISO 13485
 Specifications
Mattress (TS-505)
 Dimension (cm)L 200 x W90 x H15
 Weight~  4.2 Kg
Offloading Cycles 1-in-2
 Number of Cells 20 Retainer Air Cell
 Load Range 20 - 240 Kg
 Pillow Function 3 Cells
 Top Coverlet Material 4-way stretchable vapor permeable water resistant
Nylon PU
 Bottom Cover Material210D Nylon TPU
 Air Cell Material70D Nylon TPU
 Transport ModeYes
 Emergency CPRSingle Pull
Certification CE, FR, IEX0
HOVER AUTO IntiIoT (IT9RTSIN)

HOVER® AUTO IntiIoT with 9" RAC + CoC Mattress

Specifications
System Controller (AUTO IntiIoT)
 Dimension (cm)L 30 x W15 x H25
Weight~  3.1 Kg
Pump Flow Rate ~ 17 LPM
Automatic Modes Dynamic, Comfort, Firm, Incline
Sensors and AlarmsLow  Pressure, System Failure, Power Failure
Pressure Adjustment levels 5 Steps
Battery Backup 30 min
Alternating Cycle Time (min)
 5, 10 (default), 15, 20
Case Material Durable and non-reactive PC
Input VoltageAC 220-240V / 50Hz
IoT ConnectivityBluetooth
Certifications CE,  IEC 60601-1, IEC 60601-1-2,
IEC 62304, IP 41, ISO 13485
 Specifications
Mattress (TS-508)
 Dimension (cm)L 200 x W90 x H23
 Weight~ 8.5 Kg
Offloading Cycles 1-in-2 and static bottom
 Number of Cells 20 / 22 Retainer Air Cell +
 Cell on Cell
 Load Range 30 - 250 Kg
 Pillow Function 3 Cells
 Top Coverlet Material 4-way stretchable vapor permeable water resistant
Nylon PU
 Base Material210D / 600D Nylon TPU
 Air Cell Material70D Nylon TPU
 Transport ModeYes
 Emergency CPRSingle hand Dual Pull
CertificationCE, FR, IEX0
HOVER AUTO (AU8CXSIN)

HOVER® AUTO with 8" CoC Mattress

Specifications
System Controller (AUTO)
 Dimension (cm)L 30 x W15 x H25
Weight~ 3.0 Kg
Pump Flow Rate~ 17 LPM
Automatic Modes Dynamic, Comfort, Firm, Incline
Sensors and AlarmsLow  Pressure, System Failure, Power Failure
Pressure Adjustment levels 5 Steps
Battery Backup 30 min
Alternating Cycle Time (min)
 5, 10 (default), 15, 20
Case MaterialDurable and non-reactive PC
Input VoltageAC 220-240V / 50Hz
Fuse 1A Slow Blow Out
Certifications CE, IEC 60601-1, IEC 60601-1-2,
IP 41, ISO 13485
 Specifications
Mattress (XS-T04)
 Dimension (cm)L 200 x W90 x H20
 Weight~  6.5 Kg
Offloading Cycles 1-in-2
 Number of Cells 18 Cell-on-Cells
 Load Range 20 - 250 Kg
 Pillow Function 3 Cells
 Top Coverlet Material 4-way stretchable vapor permeable water resistant
Polyester PU

 Bottom Cover Material600D Polyester PVC
 Air Cell Material70D Nylon TPU
 Transport ModeYes
 Emergency CPRDual Pull
Certification CE
HOVER MAX (MX5TXSIN)

HOVER® MAX with 5" Mattress

Specifications
System Controller (MAX)
 Dimension (cm)L 30 x W15 x H25
Weight~  2.7 Kg
Pump Flow Rate ~ 17 LPM
Automatic Modes Dynamic, Static
Sensors and AlarmsLow  Pressure
Pressure Adjustment levels 5 Steps
Panel LockYes
Alternating Cycle Time (min)
10 min
Case Material Durable and non-reactive PC
Input VoltageAC 220-240V / 50Hz
Fuse Rating1 A SLow Blowout
Certifications CE, IP 41, ISO 13485
 Specifications
Mattress (XS-T05)
 Dimension (cm)L 200 x W90 x H13
 Weight~  4.9 Kg
Offloading Cycles 1-in-2 and static bottom
 Number of Cells 16 Air Cell
 Load Range 30 - 210 Kg
 Pillow Function 3 Cells
 Top Coverlet Material 4-way stretchable vapor permeable water resistant
Nylon PU
 Base Material600D Polyester PVC
 Air Cell Material70D Nylon TPU
 Transport ModeYes
 Emergency CPRSingle Pull
CertificationCE